Home › How we calculate
How we got 13.1 hours for the Anker SOLIX C1000 Gen 2
Every runtime on this site comes from the same sum: usable Wh ÷ (device watts + the station's own draw). Here it is for our pick, then where each number comes from.
- 1,024Whon the box (Anker SOLIX C1000 Gen 2)
- 890Whwhat an independent test got out (87%)
- 733Whruns the CPAP at 56.1W157Whkeeps the station's own inverter on at 12W
- 13.1 hoursuntil the battery is empty
| Usable energy (independent test) | 890Wh |
|---|---|
| CPAP, typical draw (ResMed) | 56.1W |
| Station's own draw (our default) | 12W |
| 890 ÷ (56.1 + 12) | 13.1 hours |
At ResMed's 73.2W peak the same sum gives 10.4 hours, the smaller number under each row of the ranking.
The usable energy comes from an independent test
A battery never gives back everything on its label. Some energy turns to heat in the cells and in the inverter (the part that makes wall power). Across the units with a published test, the middle value was 86%, so we rank on the measured figure, never the box.
| Tester | How they tested | Units | Latest test |
|---|---|---|---|
| OutdoorGearLabUS gear review site | Drained at about 80% of max output | 4 | Jul 23, 2026 |
| StorageReviewUS hardware review lab | Drained at 350W (1 unit); load not stated (2 units) | 3 | Jan 2, 2025 |
| Outdoor LifeUS outdoors magazine | Drained at about 380W | 3 | Jan 9, 2026 |
| Trusted ReviewsUK consumer tech site; tested 230V units | Drained at 200W | 1 | Mar 27, 2025 |
We use 1 figure per unit. When a tester publishes several loads, we take the 200W run if there is one, otherwise the tester's main figure, and never a low-load run, because that already includes the station's own draw and our sum adds it separately. A test done on a 230V unit is flagged in its row.
The CPAP's draw comes from ResMed
| Your CPAP draws | Hours |
|---|---|
| 28W | 22.3 |
| 40W | 17.1 |
| 56.1W | 13.1 |
| 73.2W | 10.4 |
| 100W | 7.9 |
Halving the watts doesn't double the hours, because the station's own draw stays the same all night.
The station's own draw, and other gaps we fill
| When this is missing | We use | Why |
|---|---|---|
| An independent capacity test | Rating × 0.85 | The 11 tested units gave back 78 to 93%, middle 86% |
| The maker's idle figure | 12W | The 3 units with a maker figure list 9 to 15W |
The 5 estimate rows: EcoFlow RIVER 3 Plus, Anker SOLIX C2000 Gen 2, Allpowers R1500, Oukitel P1000 Plus, Pecron E1500LFP. They sit last in the ranking and show as outlined blocks.
What we don't know
- ResMed doesn't say which pressure or humidifier setting its 56.1W assumes.
- We haven't found a maker or tester figure for humidifier off, so we can't rank for one.
- We calculate hours on AC power. Running a CPAP from the station's DC port skips the inverter and should last longer, but we haven't found a published run.
- Most tests drained the units at 200W or more. A CPAP draws about 56W, and at low loads the station's own draw takes a bigger share. Our sum adds that draw back in.
- Your unit's age, the room temperature and how full you charged it all change the real number.
One of the tests we use ran its units at about 34W and got 49 to 63% of their rated capacity out. For the Bluetti AC180, our sum with that test's 980Wh measurement and its 14W idle reading gives 60%, inside that range (59% with Bluetti's own 15W figure, which the table uses). Low loads lose a bigger share to idle draw, and the sum catches that.
Questions
- Why don't you test the units yourselves?
- We don't have a lab. Independent testers have already run these units until empty and published what they got out, so we build on their figures and link every one.
- Why do you get less than the number on the box?
- Some energy turns to heat in the battery and the inverter. The 11 tested units gave back 78 to 93% of their rating, with a middle value of 86%.
- What if my CPAP uses less power?
- Divide the usable energy by your CPAP's watts plus the idle draw. The table above shows the C1000 Gen 2 at 5 different draws.
- Can I trust an estimate row?
- It's our best guess: the rating × 0.85. Measured rows rank first for that reason, and estimate rows say so.
- How often do you update the numbers?
- We recheck stock and specs and add new tests as they're published. The date at the top of the page shows the last change to the figures.
Take the data
Download the CPAP table (CSV): every model, its rated and usable Wh, the test behind it, idle draw and hours. Free to reuse with credit (CC BY 4.0 for the calculated columns).